Hunting the Culprit: (Properly) Understanding ECG Leads

Recently I was lucky enough to have attended the ‘EMECG’ course in Cape Town, SA. It was a 2-day event that took place at the beautiful V&A waterfront.

The faculty delivered high yield, EM-centric ECG education in a hugely entertaining way, and I’m
champing at the bit to demonstrate my improved interpretation skills at work! Check out the EMECG website here, and their Facebook page here.EMECG

A particularly standout learning experience was being taught how to identify the culprit vessel when considering ST-elevation myocardial infarction. It’s a concept that I’ve always struggled to wrap my head around, and am very pleased to now have it firmly in my arsenal of ECG skills.

This will be the first in a series of posts titled ‘Hunting the Culprit’, inspired by the EMECG course:

Post 1: (Properly) Understanding ECG Leads

Post 2: Coronary artery anatomy

Post 3: STEMI Basics

Post 4: Anterior STEMI

Post 5: Inferior/Posterior STEMI

Understanding the ECG Leads

The first step towards understanding how to hunt the culprit vessel (or accurately interpret any ECG for that matter), is to go right back to basics and revise the ECG leads.

An ECG lead is a graphic representation, or ‘snapshot’, of electrical activity (depolarisation/repolarisation) within the heart. Each lead ‘looks’ at the heart from a different position, and takes an electrical photograph… so to speak! There are 12 leads on a standard ECG. More are possible depending on the clinical question being asked – this will be discussed in later posts where various types of STEMI are considered.

The position from which each lead ‘looks’ at the heart (it’s plane) is defined by a positive and negative ‘pole‘.

The positive pole is a ‘sensing’ electrode, which can be placed at various anatomical locations on the body, depending on the lead it is measuring voltage for. The negative pole is a reference point for the positive pole.

A ‘vector’ is an electrical signal that moves in a direction. When cell membranes in the heart depolarise, a vector is created. Vectors are detected by the positive pole:

  • If the vector moves towards the positive pole, there will be a positive deflection on the ECG.
  • If the vector moves away from the positive pole, there will be a negative deflection.
  • If the vector is perpendicular to the positive pole, there will be little/no deflection.

SpireColor200_1S001-3-page-001 lead-diagram

The negative pole for each ECG lead is either an electrode on the body (standard limb leads), or  ‘Wilson’s central terminal’ which is a virtual electrode – more explanation shortly…

Key point – a lead is NOT the same as an electrode! A lead is an electrical picture of the heart… An electrode measures voltage – this allows the production of a lead by a machine.

On a 12-lead ECG, the leads can be divided into 2 groups of 6:

Limb leads on the left-hand side of the ECG sheet, and the precordial/chest leads on the right:

Normal_ECG               Normal_ECG (1)

The Limb Leads

The 6 limb leads examine of the heart in a vertical/coronal plane.

Electrodes are placed on the right arm, left arm, right leg and left leg.

sagittal-heart-page-001    ECG_limb_leads_wiki

The limb leads are divided into the standard limb leads and augmented limb leads.

Standard Limb Leads

The standard limb leads (I, II, III) form ‘Eindhoven’s triangle’ – the original 3-lead ECG from 1903!

SpireColor200_1S001-page-005

They are ‘bipolar’ leads as both poles are electrodes on the body.

Lead I – right arm electrode negative pole, left arm electrode positive pole.
Lead II – right arm electrode negative pole, left leg electrode positive pole.
Lead III – left arm electrode negative pole, left leg electrode positive pole.

NB: the right leg electrode is the ‘grounding electrode‘ – it is not involved in any leads, but the ECG will not record unless the electrode is attached.

SpireColor200_1S001-3-page-003

Lead I takes a snapshot of the heart from the patient’s left-hand side, and defines 0 degrees in relation to all other limb leads (including the augmented limb leads)

Eindhoven’s triangle has the geometric properties of an equilateral triangle:

  • Lead II takes a snapshot 60 degrees further clockwise from lead I.
  • Lead III takes a snapshot a further 60 degrees from lead II.
  • I + III = II (This is ‘Eindhoven’s Law‘ – i.e. the combined measured voltages of leads I and III equal that of lead II).

Augmented Limb Leads

The standard limb leads that form Eindhoven’s triangle can be used to create a new reference point – Wilson’s central terminal. 

Wilson’s central terminal is a virtual pole that is composed of the average of the electrical potentials from the 3 standard limb leads. It is found in the centre of Eindhoven’s triangle.

Strictly, Wilson’s central terminal should be called the ‘zero’ pole, but conceptually it is easier to think about it as the ‘negative pole’ for the augmented limb leads.

SpireColor200_1S002-page-001

The augmented limb leads are ‘unipolar‘ leads (as there isn’t really a negative pole).

aVR – Wilson’s central terminal ‘negative pole’, right arm positive pole
aVL – Wilson’s central terminal ‘negative pole’, left arm positive pole
aVF – Wilson’s central terminal ‘negative pole’, left leg positive pole

(‘aV’ stands for ‘augmented vector’, and then ‘right’, ‘left’, and ‘feet’)

When you combine the standard limb leads and the augmented limb leads you get the following pattern of ‘views’ – the ‘Hexaxial System’.

SpireColor200_1S002-page-007

Remember that the limb leads look at the heart in a vertical/coronal plane.

Therefore, it becomes apparent that:

  • Leads II, III and aVF look at the inferior heart. They are, therefore, the inferior leads.
  • Leads I and aVL look at the lateral left ventricle. They, therefore, form 2 of the lateral leads (the other lateral leads are the lateral precordial leads).

This is illustrated with the hexaxial system superimposed over a heart diagram below:

150510130710_0001-page-001

During ventricular contraction there is a wave of depolarisation that creates a huge number of individual vectors.

The ‘mean vector‘ (or ‘depolarisation vector‘) is the average of all those vectors, and it is this which manifests as the electrical photograph we see on the ECG (the QRS complex).

When considering the electrical pattern during ventricular depolarisation in a normal heart (i.e. no axis deviation):

  • The initial event is a left-to-right depolarisation of the septum – a down/rightward mean vector results.
  • This is quickly followed by ventricular contractionthis results in a down/leftward mean vector. It is more leftward as the LV has a greater muscle mass than the RV.

Now the morphology of the QRS complexes in the limb leads make more sense (see diagram below!).

SpireColor200_1S001-3-page-004

The Precordial Leads

The 6 precordial leads (V1-V6) examine the flow of electrical activity through the heart in the transverse/horizontal plane.

transverse-heart-page-001

The positive poles are electrodes placed on the anterior/left lateral chest wall as illustrated below:

precordial-lead-placement

The reference point for each of these positive poles is Wilson’s central terminal. Therefore, the precordial leads are also ‘unipolar‘ leads (along with the aV leads).

SpireColor200_1S002-page-005

V1 and V2 face the surface of the right ventricle, as is demonstrated in the diagram. However, they also face the septum, which has a greater muscle mass, and therefore the leads are more strongly influenced by electrical activity in this structure. They are, therefore, known as the septal leads.

V3 and V4 takes a snapshot of the anterior wall of the LV.

V5 and V6 take a snapshot of the lateral wall of the LV.

When you put it all together…

Here is a diagram that demonstrates where all of the ECG leads examine the heart from. Imagine all the arrows pointing to eyes looking at the heart from the different positions…

SpireColor200_1S001-3-page-002

Now, interpreting an ECG becomes more like map-reading – particularly when considering STEMI and hunting the culprit vessel…

Lead-Map

Take Home Learning Points

  • Each ECG lead is an electrical ‘snapshot’ of the heart taken from a specific position.
  • Waves of depolarisation create vectors which are sensed by a positive pole (an electrode on the body).
  • A negative pole (standard limb leads), or Wilson’s central terminal (aV + precordial leads), is the reference point for each positive pole.
  • The limb leads view electrical activity in the heart in the vertical/coronal plane.
  • The precordial leads view electrical activity in the heart in the transverse/horizontal plane.
  • Understanding the anatomical area of the heart that each lead ‘looks’ at, allows mapping of pathology on the ECG.

References

 

 

Comments

  1. Andrew says

    I’m a 3rd year medical student at the University of Glasgow, I think this is an amazing description of the ECG – can’t wait for the next instalments!!

  2. Emma says

    Hands down the best explanation I’ve ever stumbled upon; I’ve never understood this properly before but it has finally clicked! Thank you so much, and please keep writing!

Trackbacks

Leave a Reply